MRC | Criteria | Characteristic |
---|
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | THREADED BUSHING AND LINE |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJX | NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 45.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 60.00 ACTUATION POINT NOMINAL GALLONS PER MINUTE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 220.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL SECOND VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE THREADED BUSHING |