If your operations demand part number RF00200, an item produced by Ems Development Corporation and listed with the description “Filter Radio Frequency Interfere,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number RF00200. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 13619 items or other various products manufactured by Ems Development Corporation. We also present a catalog of all related FSC 5915 Filters and Networks parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number RF00200 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-824-7975 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 008247975 | Y | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
RF-200 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.628 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.125 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.125 INCHES NOMINAL |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 6TH RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 WIRE HOOK OUTPUT 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
ADAT | BODY WIDTH | 1.938 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.719 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -40.0 TO 85.0 DEG CELSIUS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 3RD RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK INPUT 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |