If your operations demand part number 727803-2, an item produced by General Dynamics Ots Global Inc and listed with the description “Transformer Power,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number 727803-2. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 21562 items or other various products manufactured by General Dynamics Ots Global Inc. We also present a catalog of all related FSC 5950 Coils and Transformers parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number 727803-2 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-324-3279 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013243279 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
11-00120-002 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 1.600 INCHES MINIMUM AND 1.680 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ADAT | BODY WIDTH | 1.430 INCHES MINIMUM AND 1.470 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 11.5 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 27.5 AMPERES DC NOMINAL SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
TEST | TEST DATA DOCUMENT | 16340-11-00120 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.780 INCHES MINIMUM AND 1.820 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 120.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 140.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
FEAT | SPECIAL FEATURES | TERMINAL 20 IS COMMON TERMINAL FOR ALL SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |