If your operations demand part number 1502-15-94, an item produced by L 3 Communications Corporation and listed with the description “Capacitor Fixed Electrolytic,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number 1502-15-94. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 80045 items or other various products manufactured by L 3 Communications Corporation. We also present a catalog of all related FSC 5910 Capacitors parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number 1502-15-94 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-196-5772 Item PartTypeName: CAPACITOR,FIXED,ELECTROLYTIC | 5910 | 001965772 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
G335R | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0600 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 1.500 MICROAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
TEST | TEST DATA DOCUMENT | 80045-1502-15 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.250 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.150 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.150 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.095 INCHES MINIMUM AND 0.145 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE,W/GND TERMINAL |
AECE | ANODE TYPE | SOLID |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 3.300 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 22.5 MILLIAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 20.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -0.00 TO 20.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |