If your operations demand part number 4330-001, an item produced by Labinal Llc and listed with the description “Circuitbreaker,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number 4330-001. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 76374 items or other various products manufactured by Labinal Llc. We also present a catalog of all related FSC 5925 Circuit Breakers parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number 4330-001 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-534-4300 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015344300 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
4330-001 | 5 | 9 | D |
MRC | Criteria | Characteristic |
---|---|---|
ADAU | Body Height | 1.381 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
ABXD | Bushing Length | 0.250 INCHES NOMINAL |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 200.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CPRJ | Trip Release Method | THERMAL ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 ALL LOCATIONS |
ADAT | Body Width | 0.781 INCHES MAXIMUM |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ADAQ | Body Length | 1.840 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.438 INCHES |
THSD | Thread Series Designator | UNS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.500 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 6 TAB W/SCREW |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.624 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CMLP | Thread Quantity Per Inch | 32 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |