If your operations demand part number KC-D4A-300L, an item produced by Leach International Corporation and listed with the description “Relay Electromagnetic,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number KC-D4A-300L. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 58657 items or other various products manufactured by Leach International Corporation. We also present a catalog of all related FSC 5945 Relays and Solenoids parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number KC-D4A-300L and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-463-3569 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 014633569 | 0 | N | D | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | D | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
KC-D4A-300L | E | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 9 PIN CONTACTS |
CQYJ | Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
CSQJ | Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ADZC | Environmental Protection | HERMETIC |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 25.0 AMPERES DC RESISTIVE LOAD AND 25.0 AMPERES AC RESISTIVE LOAD |
ABMK | Overall Width | 1.025 INCHES MAXIMUM |
ABKW | Overall Height | 1.010 INCHES MAXIMUM |
CWAB | Main Contact Maximum Voltage Rating In Volts | 115.0 AC AND 28.0 DC |
ABHP | Overall Length | 1.718 INCHES MAXIMUM |
AXHR | Mounting Facility Type And Quantity | 2 BRACKET SINGLE MOUNTING FACILITY |
FEAT | Special Features | 3PDT, 25 AMP (RESISTIVE), HERMETICALLY SEALED, 28 VDC COIL, 3% PER 10,000 FAILURE RATE, RAISED VERTICAL FLANGE MOUNT, RELAY |
APCN | Coil Quantity | 1 |
MRC | Decoded Requirement | Clear Text Reply |
AYSC | Pile-Up Main Contact Form Arrangement | 3C |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES DC MOTOR LOAD AND 12.0 AMPERES AC MOTOR LOAD |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 5.0 AMPERES DC LAMP LOAD AND 5.0 AMPERES AC LAMP LOAD |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 12.0 AMPERES DC INDUCTIVE LOAD AND 15.0 AMPERES AC INDUCTIVE LOAD |
AKDX | Winding Quantity | 1 |
TTQY | Terminal Type And Quantity | 2 PIN ENERGIZING ELEMENT |
APNP | Duty Type | CONTINUOUS |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-83536/32-003L GOVERNMENT SPECIFICATION |
TEST | Test Data Document | 81349-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.