If your operations demand part number A10-1E2A-AAM, an item produced by Magnetrol International and listed with the description “Switch Liquid Level,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number A10-1E2A-AAM. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 87009 items or other various products manufactured by Magnetrol International. We also present a catalog of all related FSC 5930 Switches parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number A10-1E2A-AAM and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-905-0748 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 009050748 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A102VP | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ACYN | AC VOLTAGE RATING | UNABLE TO DECODE230.000 VOLTS NOMINAL 1ST OPERATING POWER RQMT |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | CABLE |
ALSF | INTERNAL BATTERY ACCOMMODATION | UNABLE TO DECODENOT INCLUDED 1ST OPERATING POWER RQMT |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.5 AMPERES RESISTIVE LOAD |
AWAE | FLOAT QUANTITY | 2 |
AWTN | OPERATING TEMP RATING | 100.0 DEG FAHRENHEIT MINIMUM AND 400.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | THREAD |
BBJX | MOUNTING POSITION | VERTICAL |
BJKD | CONTACT ARRANGEMENT | SPST NORMALLY OPEN |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | DIESEL OIL |
BJKN | FLOAT EFFECTIVE TRAVEL | 2.000 INCHES MAXIMUM |
BJKP | MOUNTING DIMENSIONS | 2-1/2-8 NPT THD CONNECTION |
FAAZ | PHASE | UNABLE TO DECODESINGLE 1ST OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | WITH 10 FT TYPE 316 STAINLESS STEEL FLEXIBLE CABLE STEM,DESPLACEMENT TYPE LIQUID LEVEL CONTROL,EXPLOSION PROOF AND WATERPROOF SWITCH HOUSING AND DESIGNED FOR 3/4 IN. CONDUIT WIRING |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote