If your operations demand part number 924488-1, an item produced by Northrop Grumman Systems Corporation and listed with the description “Transformer Power,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number 924488-1. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 06481 items or other various products manufactured by Northrop Grumman Systems Corporation. We also present a catalog of all related FSC 5950 Coils and Transformers parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number 924488-1 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-332-1121 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013321121 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
13442 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.440 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.460 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.020 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRMJ | WINDING POWER RATING | 0.016 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TURRET |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.970 INCHES MINIMUM AND 1.030 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 111.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ABMK | OVERALL WIDTH | 0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote