If your operations demand part number 38603, an item produced by Ranco Management Corp and listed with the description “Switch Thermostatic,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number 38603. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 49742 items or other various products manufactured by Ranco Management Corp. We also present a catalog of all related FSC 5930 Switches parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number 38603 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-449-6921 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 004496921 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
38603 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A ALL THREADED HOLE |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 2.563 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.610 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.250 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.179 INCHES MINIMUM AND 2.195 INCHES MAXIMUM |
AEVT | CAPILLARY TUBE LENGTH | 30.0 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AXGY | MOUNTING METHOD | BRACKET AND THREADED HOLE |
CBBL | FEATURES PROVIDED | AUTOMATIC RESET |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES ALL THREADED HOLE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 8.3 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE,PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | 12.00/38.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
CTYX | CONTACT STIMULUS RATING | 17.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 23.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 DC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
THSD | THREAD SERIES DESIGNATOR | UNC ALL THREADED HOLE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.