If your operations demand part number APL111-1-42F-303, an item produced by Sensata Technologies Inc and listed with the description “Circuit Breaker,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number APL111-1-42F-303. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 81541 items or other various products manufactured by Sensata Technologies Inc. We also present a catalog of all related FSC 5925 Circuit Breakers parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number APL111-1-42F-303 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-513-3077 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015133077 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
APL111-1-42F-303 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AKPX | Pole Quantity | 3 |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
BBRJ | Special Handling Feature | MAGNETIC |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CBBL | Features Provided | HIGH INRUSH PROTECTION |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.156S INCHES MINIMUM AND 2.344 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
THSD | Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.138 INCHES |
AAQL | Body Style | |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.553 INCHES MAXIMUM |
ADAQ | Body Length | 2.510 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
AGAV | End Item Identification | MULTIPLE APPLICATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 30.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
ZZZK | Specification/Standard Data | 81349-MIL-C-55629/5 GOVERNMENT SPECIFICATION |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
TEST | Test Data Document | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.