If your operations demand part number VME 910, an item produced by Taylor Electronics Inc and listed with the description “Power Supply,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number VME 910. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 0AUX5 items or other various products manufactured by Taylor Electronics Inc. We also present a catalog of all related FSC 6130 Converters Electrical Non Rotating parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number VME 910 and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-260-9518 Item PartTypeName: POWER SUPPLY | 6130 | 012609518 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | 0 | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
VME 910 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | AN/MPQ-T3 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 180.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 260.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -0.1/70.0 DEG CELSIUS |
CWWY | POWER SUPPLY EFFICIENCY LINE | 70.0 |