If your operations demand part number S1-2C-MODIFIED, an item produced by Thermotion Corp and listed with the description “Chamber Environment,” look no further than this page. At your convenience, you can complete the Request for Quote (RFQ) form below with details like your budget, desired quantity, and anticipated fulfillment timeline to receive customized procurement options on part number S1-2C-MODIFIED. Our representatives will happily treat you to competitive pricing and swift lead times upon their receipt and review of a completed form, regularly responding in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
If you are interested, be sure to explore our website further for related CAGE Code 20824 items or other various products manufactured by Thermotion Corp. We also present a catalog of all related FSC 6636 Environmental Chambers And Related Equipment parts that we currently carry for your perusal. Regardless of what you decide to purchase from us, we will work closely with you to provide dependable, authentic products while ensuring that we address every requirement possible. This being said, get started on requesting quotes for part number S1-2C-MODIFIED and any other NSN parts you need on Sky Forge Components to experience our unrivaled fulfillment services.
MRC | Criteria | Characteristic |
---|---|---|
AMSE | Voltage Rating | 115.0 VOLTS NOMINAL |
AFMQ | Inside Height | 12.000 INCHES NOMINAL |
AFMW | Outside Height | 41.000 INCHES NOMINAL |
BDWT | Heating Method | ELECTRICAL |
BLST | Insulated Cabinet | PROVIDED |
ADJT | Inside Width | 16.000 INCHES NOMINAL |
HUES | Color | BLUE |
ADJV | Outside Width | 30.000 INCHES NOMINAL |
BQMN | Outer Door Quantity | 1 |
CWZY | Environmental Chamber Type | TEMPERATURE |
FAAZ | Phase | SINGLE |
ANPT | Power Rating | 40.0 VOLT-AMPERE NOMINAL |
AKYD | Accessory Components And Quantity | 2 1/2 HORSEPOWER COMPRESSORS |
BNDW | Cooling Coils For Below Room Temp Use | INCLUDED |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL |
BQML | Cabinet Mounting Type | STAND |
BQMP | Outer Door Material | STEEL |
BGXH | Water Jacket | PROVIDED |
BQMH | Cabinet Outer Wall Material | STEEL |
BQMJ | Cabinet Inner Wall Material | STEEL |
BQMR | Outer Door Insulation Feature | INCLUDED |
BHJQ | Door | PROVIDED |
BHGT | Circulation Method | MECHANICAL |
AFEF | Inside Depth | 11.000 INCHES NOMINAL |
BCXB | Outside Depth | 22.000 INCHES NOMINAL |
SFTT | Surface Treatment | LACQUER, FED SPEC 595-25185 |
MRC | Decoded Requirement | Clear Text Reply |
ASQJ | Operating Temp Range In Deg Celsius | -73.3 TO 177.0 |
FEAT | Special Features | PROGRAMMABLE TEMPERATURE CONTROLLER WITH DIGITAL DISPLAY (MODEL 2800);6PANE THERMAL WINDOW WITH SILICONE GASKETS; RS-232C OR IEEE-488 INTERFACE;DRY NITROGEN USED TO REDUCE MOISTURE CONTENT;MODIFIED TO INCLUDE REFRACTOR COLLIMATOR, MOTORIZED TARGET WHEEL AND VIBRATION ISOLATED BASE PLATE;USED TO TEST THE B-52 FLIR SENSOR ASSEMBLY (AN/AAQ-23) AND USED IN CONJUNCTION WITH IR RADIATION SOURCE CONTROL UNIT SR-80-2D |
AFPM | Assembly Form | ASSEMBLED |
ACDC | Current Type | AC |
MATT | Material | STEEL |
AZZH | Heat Source For Which Designed | INTEGRAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote